Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Data Center Storage that are effective as of March 15, 2021 or the Version 2.1 requirements that are effective as of January 19, 2022. A detailed listing of key efficiency criteria are available at https://www.energystar.gov/products/office_equipment/data_center_storage/key_product_criteria
This dataset has the following 144 columns:
Column Name | API Column Name | Data Type | Description | Sample Values |
---|---|---|---|---|
PD_ID | pd_id | number | The ENERGY STAR Unique ID (ESUID) is a string of seven numbers EPA assigns to an ENERGY STAR model or set of models with unique performance characteristics. This ESUID is unique to both the model and product specification version and is assigned by EPA upon receipt of certification information from the certification body. Each row within the product list will have a unique ESUID. Developers may wish to use this ESUID to track information on certified models in their information systems. | 2384461 2385114 2501844 2384462 2385113 view top 100 |
ENERGY STAR Partner | energy_star_partner | text | An organization that signed a Partnership Agreement with EPA to manufacture or private label ENERGY STAR qualified products. | Dell Inc. EMC Corporation Pure Storage, Inc. NetApp, Inc. Viking Enterprise Solutions, a division of Sanmina Corp view top 100 |
Brand Name | brand_name | text | An identifier assigned by the manufacturer or private labeler to a product or family/series of products for sales and marketing purposes. | DELL Pure Storage DELL EMC NetApp Viking Enterprise Solutions view top 100 |
Model Name | model_name | text | An identifier assigned by the manufacturer or private labeler to a product or family/series of products for sales and marketing purposes. | PowerScale A300 FAS2800-Series FlashBlade//E PowerScale H700 Flashblade S200 view top 100 |
Model Number | model_number | text | A distinguishing identifier, usually alphanumeric, assigned to a product by the manufacturer or private labeler. | PowerScale A300 FlashBlade//E FAS2720 PowerScale H700 PowerScale A3000 view top 100 |
Additional Model Information | additional_model_information | text | An identifier assigned by the manufacturer or private labeler to a product or family/series of products for sales and marketing purposes. This column includes alternative means to identify the model/model family (e.g., additional model names, additional model numbers, retailer SKUs, product descriptions). | ,BSP-14,HPE FlashBlade//EC,FlashBlade//EC,; FlashBlade//EX,FlashBlade//EX, view top 100 |
UPC | upc | text | UPC codes provided by partners for ENERGY STAR certified products. The brand, model name and model number continue to serve as the identifiers used to establish certification. The UPC code data below is intended to aid in identification of ENERGY STAR models. UPC code data is not provided for all certified models. | view top 100 |
SNIA Online Taxonomy Category | snia_online_taxonomy_category | text | The SNIA Taxonomy is a categorization scheme for use in segmenting the data center storage market by end-use application and key product characteristics. The three categories eligible for ENERGY STAR certification are Online 2, Online 3, and Online 4. | NVSS Disk Set Online 4 NVSS Disk Set Online 2 Disk Set Online 3 view top 100 |
Storage Controller Implementation | storage_controller_implementation | text | A storage controller can be implemented in two different ways. Scale-up storage is a storage product comprised of a discreet storage controller (with or without redundancy), which has a full view of all the storage devices in the storage product. Incremental storage capacity is added by the addition of storage devices under the control of the existing storage controller. While Scale-out storage is a storage product capable of being comprised of two or more discreet storage controllers (with or without redundancy), combined with an overall integration or aggregation function resulting in a single storage product view for attached servers. Each discreet storage controller often has a partial view to a partition of the overall system's storage devices, but this is not a fixed requirement. Incremental storage capacity is added by the addition of storage devices under the control of the existing storage controller(s) and/or addition of additional storage devices along with additional controller(s). | Scale-Out Storage Scale-Up Storage view top 100 |
Storage Controller Manufacturer Name | storage_controller_manufacturer_name | text | The manufacturer of the installed storage controller(s). | Dell EMC Corporation Pure Storage NetApp Viking Enterprise Solutions view top 100 |
Storage Controller Model Name | storage_controller_model_name | text | An identifier assigned by the manufacturer or private labeler to the storage controller or family/series of storage controllers for sales and marketing purposes. | FlashBlade//E PowerScale H700 PowerScale A3000 Powerscale F900 with P100 Accelerator FlashBlade view top 100 |
Storage Controller Model Number | storage_controller_model_number | text | A distinguishing identifier, usually alphanumeric, assigned to the storage controller(s) by the manufacturer or private labeler. | PowerScale A300 FlashBlade//E FAS2720 PowerScale H700 PowerScale A3000 view top 100 |
Storage Controller Advanced Data Recovery Type | storage_controller_advanced_data_recovery_type | text | Advanced Data Recovery Capability is a collective term used in this specification to refer to error detection and correction features such as RAID, mirroring / grid technology, or other comparable advanced error detection and recovery systems. | OneFS Data Protection RAID VSS no view top 100 |
Capacity Optimizing Methods (COMs) | capacity_optimizing_methods_coms | text | Capacity Optimizing Methods (COMs) are the reduction of data stored on storage devices through a combination of hardware and / or software. Common COMs include thin provisioning, data deduplication, compression, and delta snapshots. | Delta Snapshots,Thin Provisioning,Compression,Data Deduplication Thin Provisioning,Compression,Data Deduplication Delta Snapshots,Thin Provisioning,Compression Thin Provisioning,Data Deduplication Data Deduplication view top 100 |
Workload Optimization Type | workload_optimization_type | text | A configuration provided by the manufacturer may be optimized for the following workload types: transaction, streaming, or capacity. Transaction is a workload type optimized for random I/O usage measured in I/O per second per watt. Streaming is a workload type optimized primarily for sequential I/O usage, measured in MiB per second per watt. Capacity is a workload type optimized for maximum storage as measured by GB (Raw Capacity) per watt. | Composite Transaction view top 100 |
Automated Storage Tiering Capable | automated_storage_tiering_capable | text | Automated Storage Tiering is the automatic movement of data between different types of storage devices. Tiering may occur within a single storage product or may span multiple storage products. For the purposes of ENERGY STAR certification, only tiering within a single storage product is applicable. | No Yes view top 100 |
Automated Storage Tiering Enabled in Hardware on Shipment | automated_storage_tiering_enabled_in_hardware_on_shipment | text | If Intelligent Power Distribution Unit (iPDU) is enabled in hardware on shipment. | Yes No view top 100 |
Software Operating Environment Name | software_operating_environment_name | text | Software operating environment/system name supported by storage configuration(s). | OneFS Microsoft Windows Storage Server 2016 Purity / FB ONTAP Purity//FB view top 100 |
Software Operating Environment Version | software_operating_environment_version | text | Software operating environment/system version supported by storage configuration(s). | 9.2.1.0 9.2.0.0 Standard Edition 4.0.2 9.3.0.0 view top 100 |
Active or Passive Cooling Enabled in Hardware on Shipment | active_or_passive_cooling_enabled_in_hardware_on_shipment | text | If Active Cooling, Passive Cooling, or both is enabled in hardware on shipment. | Active Cooling Both view top 100 |
Length of Rolling Average for Input Power (s) | length_of_rolling_average_for_input_power_s | text | If configuration(s) is/are capable of calculating an input power rolling average, the length of the rolling average is provided here. | 10 No User Selectable not capable no view top 100 |
Length of Rolling Average for Inlet Air Temperature (s) | length_of_rolling_average_for_inlet_air_temperature_s | text | If configuration(s) is/are capable of calculating an inlet air temperature, the length of the rolling average is provided here. | 10 No User Selectable not capable no view top 100 |
Power and Temperature Reporting Additional Information | power_and_temperature_reporting_additional_information | text | If additional Power and Temperature Reporting information is available, it is provided here. | view top 100 |
Trans Model Number or Config ID | trans_model_number_or_config_id | text | A distinguishing identifier, usually alphanumeric, assigned to the model or configuration by the manufacturer or private labeler. Trans indicates that this information is for the Transaction Workload Optimization Type. | view top 100 |
Trans Power Supply Unit (PSU) Type | trans_power_supply_unit_psu_type | text | The type(s) of power supply unit(s) installed. A Power Supply Unit (PSU) is a device that converts ac or dc input power to one or more dc power outputs for the purpose of powering a storage product. A storage PSU must be self-contained and physically separable from the system and must connect to the system via a removable or hard-wired electrical connection. If there is more than one power supply, each power supply's type will be separated by a semicolon. | Multi-Output view top 100 |
Trans PSU Manufacturer Name | trans_psu_manufacturer_name | text | The manufacturer of the installed PSU(s). If there is more than one power supply, each power supply's manufacturer name will be separated by a semicolon. | Delta Electronics (Thailand) PCL view top 100 |
Trans PSU Model Name | trans_psu_model_name | text | An identifier assigned by the manufacturer or private labeler to the PSU(s) for sales and marketing purposes. If there is more than one power supply, each power supply's model name will be separated by a semicolon. | TDPS-900DB A view top 100 |
Trans PSU Model Number | trans_psu_model_number | text | A distinguishing identifier, usually alphanumeric, assigned to the PSU(s) by the manufacturer or private labeler. If there is more than one power supply, each power supply's model number will be separated by a semicolon. | TDPS-900DB A view top 100 |
Trans PSU Rated Output (W) | trans_psu_rated_output_w | text | The Rated Output per installed PSU in watts. If there is more than one power supply, each power supply's rated output will be separated by a semicolon. | 900 view top 100 |
Trans PSUs 80PLUS Certification | trans_psus_80plus_certification | text | The 80PLUS certification level achieved by the PSU(s) installed. If there is more than one power supply, each power supply's certification level will be separated by a semicolon. | view top 100 |
Trans Total Amount of Cache (GB) | trans_total_amount_of_cache_gb | text | The total amount of cache available in GB. Cache is temporary storage used to transparently store transitory data and which is not directly addressable by end-user applications. Primarily used for expediting access to or from (typically) slower devices. | view top 100 |
Trans Devices Used for Cache | trans_devices_used_for_cache | text | The devices used for cache are identified here. This can be DRAM, SSD, or Other device. | view top 100 |
Trans Other Devices Used for Cache | trans_other_devices_used_for_cache | text | If Other was chosen for Trans Device Used for Cache, the type of Other device is identified here. | view top 100 |
Trans Total Num Installed Storage Devices Optimal Point | trans_total_num_installed_storage_devices_optimal_point | text | The total number of storage devices installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Trans Ratio Devices Mixed Optimal Point | trans_ratio_devices_mixed_optimal_point | text | The ratio of installed storage devices with addressable storage (not used for cache) during testing of the highest predicted deployed device(s) optimal point. If there is more than one device in the highest predicted deployed storage device, the ratio of each storage device is separated by a semicolon. | view top 100 |
Trans Installed Solid State Devices in Optimal Point | trans_installed_solid_state_devices_in_optimal_point | text | The total number of Solid State Devices installed during testing of the highest predicted deployed device(s) optimal point. If there is more than one device in the highest predicted deployed storage device, each device's number of solid state drives is separated by a semicolon. | view top 100 |
Trans Installed Rotational Devices in Optimal Point | trans_installed_rotational_devices_in_optimal_point | text | The total number of rotational devices installed during testing of the highest predicted deployed device(s) optimal point. If there is more than one device in the highest predicted deployed storage device, each device's number of rotational drives is separated by a semicolon. | view top 100 |
Trans Num of Controllers in Optimal Point | trans_num_of_controllers_in_optimal_point | text | The total number of controllers installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Trans Num Redundant Controllers Optimal Point | trans_num_redundant_controllers_optimal_point | text | The total number of redundant controllers installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Trans Number of PSUs Optimal Point | trans_number_of_psus_optimal_point | text | The total number of PSUs installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Trans Number of Redundant PSUs Optimal Point | trans_number_of_redundant_psus_optimal_point | text | The total number of redundant PSUs installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Trans Auto Tiering Enabled Optimal Point | trans_auto_tiering_enabled_optimal_point | text | If automated storage tiering (auto-tiering) was enabled during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Trans Optimal Point DATABASE Workload Test | trans_optimal_point_database_workload_test | text | The DATABASE measurement for the highest predicted deployed storage device optimal point. | view top 100 |
Trans Optimal Point VDI Workload Test | trans_optimal_point_vdi_workload_test | text | The VDI measurement for the highest predicted deployed storage device optimal point. | view top 100 |
Trans Optimal Point Ready Idle Workload Test (GB/W) | trans_optimal_point_ready_idle_workload_test_gb_w | text | The ready idle measurement for the highest predicted deployed storage device optimal point in GB per watt. | view top 100 |
Trans Storage Device 1 Type | trans_storage_device_1_type | text | The type of storage device can be either a Hard Disk Drive (HDD) or a Solid State Drive (SSD). Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Storage Device 1 Form Factor | trans_storage_device_1_form_factor | text | The form factor of storage device 1 is either 2.5 inch, 3.5 inch, or Other. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Storage Device 1 Rated Speed (RPM) | trans_storage_device_1_rated_speed_rpm | text | The rated speed of storage device 1 in RPM. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Storage Device 1 Raw Capacity (GB) | trans_storage_device_1_raw_capacity_gb | text | The raw capacity of storage device 1 in GB. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Num Devices Storage Device 1 Optimal Point | trans_num_devices_storage_device_1_optimal_point | text | The number of devices installed in storage device 1 optimal point. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Physical or Modeled Data Device 1 Optimal Point | trans_physical_or_modeled_data_device_1_optimal_point | text | The data for the storage device 1 optimal point is obtained by physically testing the system or through the use of modeled data. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Automated Tiering Enabled During Testing Device 1 | trans_automated_tiering_enabled_during_testing_device_1 | text | If automated storage tiering (auto-tiering) was enabled during testing of the storage device 1. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Device 1 Optimal Point DATABASE Workload Test | trans_device_1_optimal_point_database_workload_test | text | DATABASE measurement for storage device 1 optimal point. | view top 100 |
Trans Device 1 Optimal Point VDI Workload Test | trans_device_1_optimal_point_vdi_workload_test | text | The VDI measurement for the highest predicted deployed storage device optimal point. | view top 100 |
Trans Device 1 Optimal Point Ready Idle Wrkld Test (GB/W) | trans_device_1_optimal_point_ready_idle_wrkld_test_gb_w | text | The ready idle measurement for storage device 1 optimal point in GB per watt. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Storage Device 2 Type | trans_storage_device_2_type | text | The type of storage device can be either a Hard Disk Drive (HDD) or a Solid State Drive (SSD). Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Storage Device 2 Form Factor | trans_storage_device_2_form_factor | text | The form factor of storage device 2 is either 2.5 inch, 3.5 inch, or Other. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Storage Device 2 Rated Speed (RPM) | trans_storage_device_2_rated_speed_rpm | text | The rated speed of storage device 2 in RPM. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Storage Device 2 Raw Capacity (GB) | trans_storage_device_2_raw_capacity_gb | text | The raw capacity of storage device 2 in GB. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Num Devices Storage Device 2 Optimal Point | trans_num_devices_storage_device_2_optimal_point | text | The number of devices installed in storage device 2 optimal point. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Physical or Modeled Data Device 2 Optimal Point | trans_physical_or_modeled_data_device_2_optimal_point | text | The data for the storage device 2 optimal point is obtained by physically testing the system or through the use of modeled data. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Automated Tiering Enabled During Testing Device 2 | trans_automated_tiering_enabled_during_testing_device_2 | text | If automated storage tiering (auto-tiering) was enabled during testing of the storage device 2. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Device 2 Optimal Point DATABASE Workload Test | trans_device_2_optimal_point_database_workload_test | text | DATABASE measurement for storage device 2 optimal point. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Device 2 Optimal Point VDI Workload Test | trans_device_2_optimal_point_vdi_workload_test | text | The VDI measurement for the highest predicted deployed storage device optimal point. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Trans Device 2 Optimal Point Ready Idle Wrkld Test (GB/W) | trans_device_2_optimal_point_ready_idle_wrkld_test_gb_w | text | The ready idle measurement for storage device 2 optimal point in GB per watt. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Model Number or Config ID | stream_model_number_or_config_id | text | A distinguishing identifier, usually alphanumeric, assigned to the model or configuration by the manufacturer or private labeler. Stream indicates that this information is for the Streaming Workload Optimization Type. | view top 100 |
Stream Power Supply Unit (PSU) Type | stream_power_supply_unit_psu_type | text | The type(s) of power supply unit(s) installed. A Power Supply Unit (PSU) is a device that converts ac or dc input power to one or more dc power outputs for the purpose of powering a storage product. A storage PSU must be self-contained and physically separable from the system and must connect to the system via a removable or hard-wired electrical connection. If there is more than one power supply, each power supply's type will be separated by a semicolon. | view top 100 |
Stream PSU Manufacturer Name | stream_psu_manufacturer_name | text | The manufacturer of the installed PSU(s). If there is more than one power supply, each power supply's manufacturer name will be separated by a semicolon. | view top 100 |
Stream PSU Model Name | stream_psu_model_name | text | An identifier assigned by the manufacturer or private labeler to the PSU(s) for sales and marketing purposes. If there is more than one power supply, each power supply's model name will be separated by a semicolon. | view top 100 |
Stream PSU Model Number | stream_psu_model_number | text | A distinguishing identifier, usually alphanumeric, assigned to the PSU(s) by the manufacturer or private labeler. If there is more than one power supply, each power supply's model number will be separated by a semicolon. | view top 100 |
Stream PSU Rated Output (W) | stream_psu_rated_output_w | text | The Rated Output per installed PSU in watts. If there is more than one power supply, each power supply's rated output will be separated by a semicolon. | view top 100 |
Stream PSUs 80PLUS Certification | stream_psus_80plus_certification | text | The 80PLUS certification level achieved by the PSU(s) installed. If there is more than one power supply, each power supply's certification level will be separated by a semicolon. | view top 100 |
Stream Total Amount of Cache (GB) | stream_total_amount_of_cache_gb | text | The total amount of cache available in GB. Cache is temporary storage used to transparently store transitory data and which is not directly addressable by end-user applications. Primarily used for expediting access to or from (typically) slower devices. | view top 100 |
Stream Devices Used for Cache | stream_devices_used_for_cache | text | The devices used for cache are identified here. This can be DRAM, SSD, or Other device. | view top 100 |
Stream Other Devices Used for Cache | stream_other_devices_used_for_cache | text | If Other was chosen for Trans Device Used for Cache, the type of Other device is identified here. | view top 100 |
Stream Total Num Installed Storage Devices Optimal Point | stream_total_num_installed_storage_devices_optimal_point | text | The total number of storage devices installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Stream Ratio Devices Mixed Optimal Point | stream_ratio_devices_mixed_optimal_point | text | The ratio of installed storage devices with addressable storage (not used for cache) during testing of the highest predicted deployed device(s) optimal point. If there is more than one device in the highest predicted deployed storage device, the ratio of each storage device is separated by a semicolon. | view top 100 |
Stream Installed Solid State Devices in Optimal Point | stream_installed_solid_state_devices_in_optimal_point | text | The total number of Solid State Devices installed during testing of the highest predicted deployed device(s) optimal point. If there is more than one device in the highest predicted deployed storage device, each device's number of solid state drives is separated by a semicolon. | view top 100 |
Stream Installed Rotational Devices in Optimal Point | stream_installed_rotational_devices_in_optimal_point | text | The total number of rotational devices installed during testing of the highest predicted deployed device(s) optimal point. If there is more than one device in the highest predicted deployed storage device, each device's number of rotational drives is separated by a semicolon. | view top 100 |
Stream Num of Controllers in Optimal Point | stream_num_of_controllers_in_optimal_point | text | The total number of controllers installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Stream Num Redundant Controllers Optimal Point | stream_num_redundant_controllers_optimal_point | text | The total number of redundant controllers installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Stream Number of PSUs Optimal Point | stream_number_of_psus_optimal_point | text | The total number of PSUs installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Stream Number of Redundant PSUs Optimal Point | stream_number_of_redundant_psus_optimal_point | text | The total number of redundant PSUs installed during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Stream Auto Tiering Enabled Optimal Point | stream_auto_tiering_enabled_optimal_point | text | If automated storage tiering (auto-tiering) was enabled during testing of the highest predicted deployed device(s) optimal point. | view top 100 |
Stream Optimal Point VDA Workload Test | stream_optimal_point_vda_workload_test | text | The VDA measurement for the highest predicted deployed storage device optimal point. | view top 100 |
Stream Optimal Point Ready Idle Workload Test (GB/W) | stream_optimal_point_ready_idle_workload_test_gb_w | text | The ready idle measurement for the highest predicted deployed storage device optimal point in GB per watt. | view top 100 |
Stream Storage Device 1 Type | stream_storage_device_1_type | text | The type of storage device can be either a Hard Disk Drive (HDD) or a Solid State Drive (SSD). Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Storage Device 1 Form Factor | stream_storage_device_1_form_factor | text | The form factor of storage device 1 is either 2.5 inch, 3.5 inch, or Other. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Storage Device 1 Rated Speed (RPM) | stream_storage_device_1_rated_speed_rpm | text | The rated speed of storage device 1 in RPM. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Storage Device 1 Raw Capacity (GB) | stream_storage_device_1_raw_capacity_gb | text | The raw capacity of storage device 1 in GB. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Num Devices Storage Device 1 Optimal Point | stream_num_devices_storage_device_1_optimal_point | text | The number of devices installed in storage device 1 optimal point. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Physical or Modeled Data Device 1 Optimal Point | stream_physical_or_modeled_data_device_1_optimal_point | text | The data for the storage device 1 optimal point is obtained by physically testing the system or through the use of modeled data. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Automated Tiering Enabled During Testing Device 1 | stream_automated_tiering_enabled_during_testing_device_1 | text | If automated storage tiering (auto-tiering) was enabled during testing of the storage device 1. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Device 1 Optimal Point VDA Workload Test | stream_device_1_optimal_point_vda_workload_test | text | The VDA measurement for the highest predicted deployed storage device optimal point. | view top 100 |
Stream Device 1 Optimal Point Ready Idle Wrkld Test (GB/W) | stream_device_1_optimal_point_ready_idle_wrkld_test_gb_w | text | The ready idle measurement for the highest predicted deployed storage device optimal point in GB per watt. | view top 100 |
Stream Storage Device 2 Type | stream_storage_device_2_type | text | The type of storage device can be either a Hard Disk Drive (HDD) or a Solid State Drive (SSD). Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Storage Device 2 Form Factor | stream_storage_device_2_form_factor | text | The form factor of storage device 2 is either 2.5 inch, 3.5 inch, or Other. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Storage Device 2 Rated Speed (RPM) | stream_storage_device_2_rated_speed_rpm | text | The rated speed of storage device 2 in RPM. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Storage Device 2 Raw Capacity (GB) | stream_storage_device_2_raw_capacity_gb | text | The raw capacity of storage device 2 in GB. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Num Devices Storage Device 2 Optimal Point | stream_num_devices_storage_device_2_optimal_point | text | The number of devices installed in storage device 2 optimal point. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Physical or Modeled Data Device 2 Optimal Point | stream_physical_or_modeled_data_device_2_optimal_point | text | The data for the storage device 2 optimal point is obtained by physically testing the system or through the use of modeled data. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Automated Tiering Enabled During Testing Device 2 | stream_automated_tiering_enabled_during_testing_device_2 | text | If automated storage tiering (auto-tiering) was enabled during testing of the storage device 2. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Stream Device 2 Optimal Point VDA Workload Test | stream_device_2_optimal_point_vda_workload_test | text | The VDA measurement for the highest predicted deployed storage device optimal point. | view top 100 |
Stream Device 2 Optimal Point Ready Idle Wrkld Test (GB/W) | stream_device_2_optimal_point_ready_idle_wrkld_test_gb_w | text | The ready idle measurement for the highest predicted deployed storage device optimal point in GB per watt. | view top 100 |
Comp Model Number or Config ID | comp_model_number_or_config_id | text | A distinguishing identifier, usually alphanumeric, assigned to the model or configuration by the manufacturer or private labeler. | PowerScale H700 PowerScale A3000 PowerScale H7000 FlashBlade / S200 view top 100 |
Comp Power Supply Unit (PSU) Type | comp_power_supply_unit_psu_type | text | The type(s) of power supply unit(s) installed. A Power Supply Unit (PSU) is a device that converts ac or dc input power to one or more dc power outputs for the purpose of powering a storage product. A storage PSU must be self-contained and physically separable from the system and must connect to the system via a removable or hard-wired electrical connection. If there is more than one power supply, each power supply's type will be separated by a semicolon. | Multi Output Multi-Output view top 100 |
Comp PSU Manufacturer Name | comp_psu_manufacturer_name | text | The manufacturer of the installed PSU(s). | Lite-On Power Technology Artesyn Lite-On Artesyn Embedded Technolgies view top 100 |
Comp PSU Model Name | comp_psu_model_name | text | An identifier assigned by the manufacturer or private labeler to the PSU(s) for sales and marketing purposes. | CSU2400AP-3-400 L1100E-S1 E750-S1 L750E-S0 view top 100 |
Comp PSU Model Number | comp_psu_model_number | text | A distinguishing identifier, usually alphanumeric, assigned to the PSU(s) by the manufacturer or private labeler. If there is more than one power supply, each power supply's model number will be separated by a semicolon. | CSU2400AP-3-400 E750-S1 PS-2112-13D-LF PS-2751-13D1 view top 100 |
Comp PSU Rated Output (W) | comp_psu_rated_output_w | text | The Rated Output per installed PSU in watts. If there is more than one power supply, each power supply's rated output will be separated by a semicolon. | 1100 2400 750W 1450 view top 100 |
Comp PSUs 80PLUS Certification | comp_psus_80plus_certification | text | The 80PLUS certification level achieved by the PSU(s) installed. If there is more than one power supply, each power supply's certification level will be separated by a semicolon. | Platinum view top 100 |
Comp Total Amount of Cache (GiB) | comp_total_amount_of_cache_gib | text | The total amount of cache available in GB. Cache is temporary storage used to transparently store transitory data and which is not directly addressable by end-user applications. Primarily used for expediting access to or from (typically) slower devices. | 384.00 2160.00 640.00 1536.00 view top 100 |
Comp Devices Used for Cache | comp_devices_used_for_cache | text | The devices used for cache are identified here. This can be DRAM, SSD, or Other device. | DRAM view top 100 |
Comp Other Devices Used for Cache | comp_other_devices_used_for_cache | text | If Other was chosen for Trans Device Used for Cache, the type of Other device is identified here. | view top 100 |
Comp Installed Rotational Devices in Optimal Point | comp_installed_rotational_devices_in_optimal_point | text | The total number of rotational devices installed during testing of the highest predicted deployed device(s) optimal point. If there is more than one device in the highest predicted deployed storage device, each device's number of rotational drives is separated by a semicolon. | 0 4 80 60 view top 100 |
Comp Num of Controllers in Optimal Point | comp_num_of_controllers_in_optimal_point | text | The total number of controllers installed during testing of the highest predicted deployed device(s) optimal point. | 1 4 2 view top 100 |
Comp Num Redundant Controllers Optimal Point | comp_num_redundant_controllers_optimal_point | text | The total number of redundant controllers installed during testing of the highest predicted deployed device(s) optimal point. | 0 1 2 view top 100 |
Comp Number of PSUs Optimal Point | comp_number_of_psus_optimal_point | text | The total number of PSUs installed during testing of the highest predicted deployed device(s) optimal point. | 2 4 view top 100 |
Comp Number of Redundant PSUs Optimal Point | comp_number_of_redundant_psus_optimal_point | text | The total number of redundant PSUs installed during testing of the highest predicted deployed device(s) optimal point. | 2 4 view top 100 |
Comp Auto Tiering Enabled Optimal Point | comp_auto_tiering_enabled_optimal_point | text | If automated storage tiering (auto-tiering) was enabled during testing of the highest predicted deployed device(s) optimal point. | No view top 100 |
Comp Optimal Point SW Build Workload Test | comp_optimal_point_sw_build_workload_test | text | The SW Build measurement for the highest predicted deployed storage device optimal point | 0.05 0.01 0.03 0.93 view top 100 |
Comp Optimal Point Ready Idle Workload Test (GB/W) | comp_optimal_point_ready_idle_workload_test_gb_w | text | The ready idle measurement for the highest predicted deployed storage device optimal point in GB per watt. | 786.90 173.08 18.58 38.50 view top 100 |
Comp Storage Device 1 Type | comp_storage_device_1_type | text | The type of storage device can be either a Hard Disk Drive (HDD) or a Solid State Drive (SSD). Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Storage Device 1 Form Factor | comp_storage_device_1_form_factor | text | The form factor of storage device 1 is either 2.5 inch, 3.5 inch, or Other. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Storage Device 1 Rated Speed (RPM) | comp_storage_device_1_rated_speed_rpm | text | The rated speed of storage device 1 in RPM. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Storage Device 1 Raw Capacity (GiB) | comp_storage_device_1_raw_capacity_gib | text | The raw capacity of storage device 1 in GB. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Num Devices Storage Device 1 Optimal Point | comp_num_devices_storage_device_1_optimal_point | text | The number of devices installed in storage device 1 optimal point. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Physical or Modeled Data Device 1 Optimal Point | comp_physical_or_modeled_data_device_1_optimal_point | text | The data for the storage device 1 optimal point is obtained by physically testing the system or through the use of modeled data. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Automated Tiering Enabled During Testing Device 1 | comp_automated_tiering_enabled_during_testing_device_1 | text | If automated storage tiering (auto-tiering) was enabled during testing of the storage device 1. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Device 1 Optimal Point SW Build Workload Test | comp_device_1_optimal_point_sw_build_workload_test | text | The SW Build measurement for the highest predicted deployed storage device optimal point | view top 100 |
Comp Device 1 Optimal Point Ready Idle Workload Test (GB/W) | comp_device_1_optimal_point_ready_idle_workload_test_gb_w | text | The ready idle measurement for storage device 1 optimal point in GB per watt. Storage device 1 is the first device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Storage Device 2 Type | comp_storage_device_2_type | text | The type of storage device can be either a Hard Disk Drive (HDD) or a Solid State Drive (SSD). Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Storage Device 2 Form Factor | comp_storage_device_2_form_factor | text | The form factor of storage device 2 is either 2.5 inch, 3.5 inch, or Other. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Storage Device 2 Rated Speed (RPM) | comp_storage_device_2_rated_speed_rpm | text | The rated speed of storage device 2 in RPM. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Cap Storage Device 2 Raw Capacity (GB) | cap_storage_device_2_raw_capacity_gb | text | The raw capacity of storage device 2 in GB. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Num Devices Storage Device 2 Optimal Point | comp_num_devices_storage_device_2_optimal_point | text | The number of devices installed in storage device 2 optimal point. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Physical or Modeled Data Device 2 Optimal Point | comp_physical_or_modeled_data_device_2_optimal_point | text | The data for the storage device 2 optimal point is obtained by physically testing the system or through the use of modeled data. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Automated Tiering Enabled During Testing Device 2 | comp_automated_tiering_enabled_during_testing_device_2 | text | If automated storage tiering (auto-tiering) was enabled during testing of the storage device 2. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Comp Device 2 Optimal Point SW Build Workload Test | comp_device_2_optimal_point_sw_build_workload_test | text | The SW Build measurement for the highest predicted deployed storage device optimal point | view top 100 |
Comp Device 2 Optimal Point Ready Idle Workload Test (GB/W) | comp_device_2_optimal_point_ready_idle_workload_test_gb_w | text | The ready idle measurement for storage device 2 optimal point in GB per watt. Storage device 2 is the second device in addition to the highest predicted deployed storage device. | view top 100 |
Date Available On Market | date_available_on_market | calendar_date | The date that the model is available for purchase. | 2021-09-07T00:00:00.000 2020-06-16T00:00:00.000 2018-05-01T00:00:00.000 2018-05-11T00:00:00.000 2022-07-20T00:00:00.000 view top 100 |
Date Qualified | date_qualified | calendar_date | The date on which the product was confirmed to meet the ENERGY STAR specification. | 2021-09-21T00:00:00.000 2020-09-10T00:00:00.000 2023-05-25T00:00:00.000 2021-10-07T00:00:00.000 2022-05-19T00:00:00.000 view top 100 |
Markets | markets | text | Includes products sold in the U.S. and/or Canada and other ENERGY STAR partner countries. | United States, Canada view top 100 |
ENERGY STAR Model Identifier | energy_star_model_identifier | text | A unique string of characters assigned by certificationbodies (CBs) to identify a model or set of models with the same performancecharacteristics. This identifier should remain the same for a model even if itis recertified to a new version of an ENERGY STAR specification. This string ofcharacters is determined by CBs and is not the ENERGY STAR Unique ID assignedby EPA. | ES_29573_Powerscale F900_09212021151924_3594628 ES_29573_Powerscale F200_08062021151110_1740944 FlashBlade//E ES_1093185_FAS2820_20237101105227_3574705 Flashblade S200 view top 100 |