- API
Low Noise Millimeter Wave LNA Project
nasa-test-0.demo.socrata.com | Last Updated 2015-07-20T05:24:11.000ZThe Phase I effort will result in a low noise MMIC G-Band amplifier the covers the entire 165 to 193GHz frequency range. The amplifier will be designed using a 50nm MHEMT that has already been developed by BAE Systems that enables the state-of-the-art performance to be achieved. The innovative amplifier design will have a gain of 20dB, a noise figure of less than 6dB(~4dB, an input output VSWR of less than 2:1. In addition, the MHEMT has the added advantage of having lower noise power stability and 1/f noise than InP devices. A balanced amplifier is the primary approach while a single ended unit will be investigated for missions that require reduced bandwidths. The MMIC amplifier will be designed to be inserted into a waveguide housing for additional and environmental testing in a Phase II program. At completion of the Phase II program, the amplifier will be capable of being space qualified for NASA missions.
- API
Ultra Low Noise 1.06 Micron Laser Oscillator Project
nasa-test-0.demo.socrata.com | Last Updated 2015-07-20T05:29:00.000ZThe Laser Interferometer Space Antenna (LISA) demand state-of-the-art ultra-stable and low noise coherent lasers. This is a proposal to develop a space qualified high power, single mode, low noise and narrow linewidth fiber laser based on a"virtual ring" laser cavity at the 1.06 micron spectral band. This novel laser architecture enables traveling-wave oscillation in a compact, linear and all-fiber cavity. This leads to unprecedented low noise and stable laser oscillator. The all fiber device also offers a highly reliable, compact and power conserving solution. We have already demonstrated virtual ring oscillators at the 1.55 micron band that rival the state of the ring laser architecture. In this research we will develop a 1.06 micron laser that can meet or exceed the LISA experiment required laser specifications.
- API
2008 Environmental Performance Index (EPI)
nasa-test-0.demo.socrata.com | Last Updated 2015-07-19T07:26:08.000ZThe 2008 Environmental Performance Index (EPI) centers on two broad environmental protection objectives: (1) reducing environmental stresses on human health, and (2) promoting ecosystem vitality and sound natural resource management. Derived from a careful review of the environmental literature, these twin goals mirror the priorities expressed by policymakers. Environmental health and ecosystem vitality are gauged using 25 indicators tracked in six well-established policy categories: Environmental Health (Environmental Burden of Disease, Water, and Air Pollution), Air Pollution (effects on ecosystems), Water (effects on ecosystems), Biodiversity and Habitat, Productive Natural Resources (Forestry, Fisheries, and Agriculture), and Climate Change. The 2008 EPI utilizes a proximity-to-target methodology in which performance on each indicator is rated on a 0 to 100 scale (100 represents at target). By identifying specific targets and measuring how close each country comes to them, the EPI provides a foundation for policy analysis and a context for evaluating performance. Issue-by-issue and aggregate rankings facilitate cross-country comparisons both globally and within relevant peer groups. The 2008 EPI is the result of collaboration among the Yale Center for Environmental Law and Policy (YCELP), Columbia University Center for International Earth Science Information Network (CIESIN), World Economic Forum (WEF), and the Joint Research Centre (JRC), European Commission.
- API
Global Fire Emissions Database, Version 3.1
nasa-test-0.demo.socrata.com | Last Updated 2015-07-20T05:06:48.000ZThis data set provides monthly burned area, and monthly, and annual fire emissions data from July 1996 to February 2012. Emissions data are available for carbon (C), dry matter (DM), carbon dioxide (CO2), carbon monoxide (CO), methane (CH4), hydrogen (H2), nitrous oxide (N2O), nitrogen oxides (NOx), non-methane hydrocarbons (NMHC), organic carbon (OC), black carbon (BC), particulate matter 2.5 micron (PM2p5), total particulate matter (TPM), and sulfur dioxide (SO2). The C4 fraction of carbon emissions is also provided. The annual C emissions estimates were derived by combining burned area data with a biogeochemical model, CASA-Global Fire Emissions Database (CASA-GFED), that estimates fuel loads and combustion completeness for each monthly time step. The fuel loads were based on satellite derived information on vegetation characteristics and productivity to estimate carbon input and carbon outputs through heterotrophic respiration, herbivory, and fires. Note that while most emissions estimates included data for 32 variables (trace gases, aerosols, and carbon), not all data are available for all years, and not all variables (emission species) are included in each data product.Additional information may be obtained from the Global Fire Data website: http://www.globalfiredata.org/index.html. Data products include:- 0.5 degree x 0.5 degree gridded monthly burned area data (ha) for 1996 to 2012 provided as text files and as GeoTIFF files for 1996 to 2012.- 3-Hourly emssions (fraction) for 2003 to 2010 in NetCDF (.nc) format.- Daily emssions (fraction) for 2003 to 2010, in NetCDF (.nc) format.- Monthly emissions for 32 variables from 1997 to 2011, in text and GeoTIFF format.- Monthly emissions for 31 variables from specific sources (grassland and savanna, woodland, deforestation & degradation, forest, agricultural waste burning, and peat fires), both as absolute and relative emissions. The time period is for 2007 to 2011, and the files are provided in text and GeoTIFF format.- Global emission totals of C and other species from all sources, and from each individual source (forest fires, peat fires, agricultural waste burning, etc).- Annual emissions of carbon and other trace gases for all countries, for the period 1997 to 2010, provided as text files. These files are for indicative use only; they are not suitable for official reporting due to large uncertainties and potential for missing key regional aspects in the global approach used.- Ancillary data for monthly biosphere fluxes. The CASA-GFED biosphere flux sources include Net Primary Production (NPP), Heterotrophic respiration (Rh), and fires (biomass burning). These files are for the time period 1997 to 2009 and are provided as text files and in GeoTIFF format.
- API
ATSDR Hazardous Waste Site Polygon Data with CIESIN Modifications, Version 2
nasa-test-0.demo.socrata.com | Last Updated 2015-07-20T04:34:05.000ZThe Agency for Toxic Substances and Disease Registry (ATSDR) Hazardous Waste Site Polygon Data with CIESIN Modifications, Version 2 is a database providing georeferenced data for 1,572 National Priorities List (NPL) Superfund sites. These were selected from the larger set of the ATSDR Hazardous Waste Site Polygon Data, Version 2 data set with polygons from May 26, 2010. The modified data set contains only sites that have been proposed, currently on, or deleted from the final NPL as of October 25, 2013. Of the 2,080 ATSDR polygons from 2010, 1,575 were NPL sites but three sites were excluded - 2 in the Virgin Islands and 1 in Guam. This data set is modified by the Columbia University Center for International Earth Science Information Network (CIESIN). The modified polygon database includes all the attributes for these NPL sites provided in the ATSDR GRASP Hazardous Waste Site Polygon database and selected attributes from the EPA List 9 Active CERCLIS sites and SCAP 12 NPL sites databases. These polygons represent sites considered for cleanup under the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA or Superfund). The Geospatial Research, Analysis, and Services Program (GRASP, Division of Health Studies, Agency for Toxic Substances and Disease Registry, Centers for Disease Control and Prevention) has created site boundary data using the best available information for those sites where health assessments or consultations have been requested.
- API
Agency for Toxic Substances and Disease Registry (ATSDR) Hazardous Waste Site Polygon Data, 1996
nasa-test-0.demo.socrata.com | Last Updated 2015-07-19T07:26:48.000ZThe Agency for Toxic Substances and Disease Registry (ATSDR) Hazardous Waste Site Polygon Data, 1996 consists of 2042 polygons for selected hazardous waste sites that were compiled in January 1996. The Hazardous Waste Site ATSDR layer was created by linking HAZ_SITES_ATSDR_BASE with additional data. Most polygons represent sites considered for cleanup under the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA or Superfund). Typical sites are either on the EPA National Priorities List (NPL) or are being considered for inclusion on the NPL. This dataset is distributed by the Columbia University Center for International Earth Science Information Network (CIESIN). (Suggested Usage: To provide a polygon dataset of hazardous waste sites in the United States, which can be used to identify nearby populations and assess their potential risk)
- API
Photonic antenna enhanced middle wave and longwave infrared focal plane array with low noise and high operating temperature Project
nasa-test-0.demo.socrata.com | Last Updated 2015-07-20T05:33:59.000ZPhotodetectors and focal plane arrays (FPAs) covering the middle-wave and longwave infrared (MWIR/LWIR) are of great importance in numerous NASA applications, including earth remote sensing for carbon-based trace gases, Lidar mapping for earth resource locating, and environment and atmosphere monitoring. Existing MWIR/LWIR photodetectors have a low operating temperature of below 77K. The requirement for cryogenic cooling systems adds cost, weight and reliability issues, making it unsuitable for satellite remote sensing applications. This STTR project aims to develop a new plasmonic photonic antenna coupled MWIR/LWIR photodetector and FPA with significantly enhanced performance and a high operating temperature. In Phase I, we developed a preliminary plasmonic photonic antenna enhanced MWIR/LWIR photodetector and demonstrated significant enhancement in photodetectivity and operating temperature. Antenna directivity is also tested and agrees with the simulation. The phase I results not only demonstrated the feasibility of achieving high performance MWIR/LWIR photodetector using the proposed innovation, but also show its promising potentials for high operating temperature FPA development. Motivated by the successful feasibility demonstration and the promising potentials, in this STTR Phase II project, we will develop a prototype of the plasmonic photonic antenna enhanced MWIR/LWIR FPA with a high operating temperature and demonstrate its earth remote sensing capability.
- API
Low Cost Variable Conductance Heat Pipe for Balloon Payload Project
nasa-test-0.demo.socrata.com | Last Updated 2015-07-20T05:08:14.000ZWhile continuously increasing in complexity, the payloads of terrestrial high altitude balloons need a thermal management system to reject their waste heat and to maintain a stable temperature as the air (sink) temperature swings from as cold as -90<SUP>o</SUP>C to as hot as +40<SUP>o</SUP>C. Currently, constant conductance, copper-methanol heat pipes are utilized on balloon payloads to remove the waste heat. It would be desirable to use a Variable Conductance Heat Pipe (VCHP) instead, to allow the thermal resistance to increase under cold operating or cold survival environment conditions, keeping the instrument section warm. In spacecraft, thermal management is achieved using axially-grooved aluminum-ammonia heat pipes and VCHPs, which are relatively expensive to manufacture and validate. Advanced Cooling Technologies, Inc. (ACT) is proposing a low-cost VCHP based on smooth-bore, thin-wall stainless steel tubing, with either methanol or pentane as working fluids, that is capable of passively maintaining a relatively constant evaporator (payload) temperature while the sink temperature varies between -90<SUP>o</SUP>C and +40<SUP>o</SUP>C. The thin wall will be much lighter and will provide much better temperature control due to its higher thermal resistance, while the combination of working fluid and envelope material result in a heat pipe that is much less expensive to manufacture than standard grooved aluminum heat pipes. Spacecraft VCHPs normally have the gas reservoir at the end of the condenser, and maintain its temperature with electrical heaters. The proposed VCHP moves the reservoir near the evaporator, eliminating the need for electrical power to control the temperature. Preliminary calculations show that either system, methanol based or pentane based, is capable of meeting the thermal performance requirements. For both the pentane and methanol systems, the evaporator (payload) temperature varies less than 6<SUP>o</SUP>C while the heat sink temperature varies from 90<SUP>o</SUP>C to +40<SUP>o</SUP>C.
- API
Electronic Correlated Noise Calibration Standard for Interferometric and Polarimetric Microwave Radiometers Project
nasa-test-0.demo.socrata.com | Last Updated 2015-07-20T05:30:10.000ZA new type of calibration standard is proposed which produces a pair of microwave noise signals to aid in the characterization and calibration of correlating radiometers. The proposed Correlated Noise Calibration Standard (CNCS) is able to generate pairs of broad bandwidth stochastic noise signals with a wide variety of statistical properties. The CNCS can be used with synthetic aperture interferometers to generate specific visibility functions. It can be used with fully polarimetric radiometers to generate specific 3rd and 4th Stokes parameters of brightness temperature. It can also be used with spectrometers to generate specific power spectra and autocorrelations. It is possible to combine these features and, for example, generate the pair of signals that would be measured by a fully polarimetric, spectrally resolving, synthetic aperture radiometer at a particular pair of polarizations and antenna baselines for a specified scene over a specified frequency band. The proposed CNCS will cover all the frequencies used for radiometric observations in the 1 to 40 GHz range. In specific, the Phase II project will develop the system prototypes for L and X bands. While intended for ground based characterization of radiometer systems, the technological approach is amenable to on-orbit calibration.
- API
High Performance Negative Feedback Near Infrared Single Photon Counting Detectors & Arrays Project
nasa-test-0.demo.socrata.com | Last Updated 2015-07-20T05:07:52.000ZAmplification Technologies Inc ("ATI") proposes to develop the enabling material and device technology for the design of ultra low noise, high gain and high speed near-infrared single photon counting photodetectors and arrays sensitive in the 1000 nm to 1600 nm spectral region for long range space communication applications, based on the already proven mechanism of internal discrete amplification technology in InGaAs/InP material system. We plan to achieve this by using the concept of internal discrete amplification mechanism in the InP material system that gave state of the art performance parameters in the 1000 to 1600nm wavelength range and the developed device design as part of the Phase I program that shows higher detection efficiency and lower jitter performance. The primary accomplishments from the Phase II effort would be the development of ultra low noise (low jitter), high detection efficiency, very high gain and high speed near-infrared photodetectors and arrays sensitive in the 1000 nm to1600 nm spectral region. The technology of internal discrete amplification enables the combination of high speed, very high gain and ultra low noise because the internal discrete amplification nullifies the effect of impact ionization coefficients and prevents the edge break down, with high detection efficiency and high speed of operation. These photodetectors might also be used in missile seekers, battlefield target identification and recognition systems, and eye-safe LADAR. Potential civilian applications include fiber-optic telecommunications, remote sensing and laser spectroscopy.